Kbmd-240d manual




















Plug-in Horsepower Resistor Required The control must have a Plug-in Horsepower Resistor installed; purchased separately Plug-in Line Fuse Included Fuse is included with the control Plug-in Armature Fuse Available Provisions for mounting the fuse is provided, but the fuse is not included with the control.

Plug-in Horsepower Resistor. The control must have a Plug-in Horsepower Resistor installed; purchased separately. Plug-in Line Fuse. Plug-in Armature Fuse. Provisions for mounting the fuse is provided, but the fuse is not included with the control.

Plug-in Armature Fuses purchased separately. Enable Circuit. Internal Connection Diagram. Connection Diagrams for Available Options. These instructions are to be used as a reference only and are not intended to replace the detailed instructions provided herein.

You must read the Safety Warning on page 2 before proceeding. Connect ground wire earth to green ground screw on case. Permanent Magnet PM Type. See sec. II, C, on page 7. Shunt Wound Motors. Connect motor armature as above. Connect full voltage shunt field wires 90 volt motors with volt fields and volt motors with volt fields to F1 and F2.

Connect half voltage field wires 90 volt motors with 50 volt fields and volt motors with volt fields to F1 and L1. IV, C, on page Jumper J1 is factory set for speed control operation SPD. For torque control, set J1 to TRQ position. II, A, on page 5. Jumper J4 is factory set for 10 amp motors 10A. For lower amperage motors, place J4 in the proper position.

See section II, D, on page 8 for details. All trimpots have been factory set in accordance with figure 1, page 3 and table 1, page 5. VIII on page The correct size armature fuse must be installed , depending on the rating of the motor. Control will not operate if fuse is not installed.

See section V, B on page 13 and table 6 on page This switch must be used to start the control each time AC power is lost. To override this function see sec IV, G, p. This product should be installed and serviced by a qualified technician, electrician or electrical maintenance person familiar with its operation and the hazards involved.

Eye protection must be worn and insulated adjustment tools must be used when working with control under power. This product is constructed of materials plastics, metals, carbon, silicon, etc.

Proper shielding, grounding and filtering of this product can reduce the emission of radio frequency interference RFI which may adversely affect sensitive electronic equipment. If information is required on this product, contact our factory. It is the responsibility of the equipment manufacturer and individual installer to supply this safety warning to the ultimate user of this product.

However, these circuits are never to be used as safety disconnects since they are not fail-safe. Use only the AC line for this purpose. Be sure to follow all instructions carefully. This product complies with all CE directives pertinent at the time of manufacture.

Contact factory for detailed installation instructions and Declaration of Conformity. Its housing is ruggedly constructed of die cast aluminum, protected with an acrylic coating that provides excellent corrosion resistance.

All switches are sealed with rubber boots and the main speed potentiometer contains a shaft seal. The electronics for the KBPC is state-of-the-art and includes short circuit and transient protection which provides the ultimate in reliability. Electronic overload protection prevents motor burnout and demagnetization of PM motors. The control can be operated in either the Speed or Torque mode via jumper selection.

The current range, which is also jumper selectable, eliminates the necessity for calibration of IR Compensation and Current Limit for most applications. Fire or electrocution can result due to improper use of this product. Read Safety Warning. Bold indicates factory setting. See fig. Note: Factory. The range of output speed can be adjusted with the MIN. The motor will maintain the preset speed as long as the maximum load does not exceed the current limit set point. If the motor load exceeds the current limit setting, the Overload LED will turn on and the motor will stall.